contrAA 800 Series Atomic Absorption. Redefined.

  • Fast multi-element analysis
  • Accurate results with maximum precision
  • Extended measuring range

Multi-element analysis and ease of use at a manageable cost. The contrAA 800 combines the best of standard AAS instruments and ICP-OES spectrometers. Take your demand for precision and performance to the next level and cover the entire range of AAS with a single lamp.

Any Wavelength. Any Element. Any Time.

  • Xenon short arc lamp as single light soruce for all applications
  • Reduce measurement time by up to 30 % thanks to fast-sequential analysis
  • Real simultaneous measurement for selected applications
  • Flexible method development with 3D visualization of absorption spectra
  • Determination of metals, semi-metals metalloids and even non-metals

Download Product Information

High-Resolution Continuum Source (HR-CS) AAS

With the contrAA 800, lamp change in AAS is past. Only one light-intensive lamp, a xenon short arc lamp, covers the entire wavelength range of AAS. A high-resolution spectrometer with CCD detector gives a 3D spectrum and provides a maximum confidence in results and the best detection limits down to the sub ppb range. Fast sequential and multi-element measurements reduce the measurement time and maximize the sample throughput. With the spectral background correction automated by software routines (ABC and CSI-tool) even difficult samples can be analyzed easily. An elaborate design combines this unique optics with all atomization techniques, the flame, graphite furnace and hydride technique in a single platform. A wide range of intelligent accessories maximizes productivity, safety and ease of use for analytical routines. With the fully automated direct solid analysis you can skip the effort of sample digestion.

Products

Applications

Chemical & Materials

Show applications

Applications

  • Determination of PFAS in Soil and Sewage Sludge as a Sum Parameter EOF (Extractable Organically Bound Fluorine) (EN)

    Open application

  • Bestimmung von PFAS in Böden und Klärschlämmen als Summenparameter EOF (extrahierbares organisch gebundenes Fluor) (DE)

    Open application

  • Determination of trace and minor elements in alloys with solid AA (EN)

    Open application

  • Bestimmung von Spuren- und Nebenelementen in Legierungen (DE)

    Open application

Environment

Show applications

Applications

  • A Novel Method for the Fast, Sensitive, and Simple Analysis of Total Fluorine in Wastewater (JP)

    Open application

  • EOF (抽出性有機結合フッ素)の総量としての土壌や下水汚泥中のPFASの定量 (JP)

    Open application

  • Determination of PFAS in Soil and Sewage Sludge as a Sum Parameter EOF (Extractable Organically Bound Fluorine) (EN)

    Open application

  • Bestimmung von PFAS in Böden und Klärschlämmen als Summenparameter EOF (extrahierbares organisch gebundenes Fluor) (DE)

    Open application

  • Bestimmung von EOF in Oberflächengewässern mit Molekülabsorptionsspektrometrie (DE)

    Open application

  • A Novel Method for the Fast, Sensitive, and Simple Analysis of Total Fluorine in Wastewater (EN)

    Open application

  • Determination of Extractable Organically Bound Fluorine (EOF) in Surface Water (JP)

    Open application

  • Fast-sequential analysis of toxic elements in wastewater and sewage sludge by HR-CS AAS (EN)

    Open application

  • Schnell-seuqentielle Analyse giftiger Elemente in Abwasser und Klärschlamm mit der HR-CS AAS (DE)

    Open application

  • Determination of EOF in surface water with molecular absorption spectrometry (EN)

    Open application

Food & Agriculture

Show applications

Applications

  • Determination of Element Contents in Wine Using HR-CS Flame AAS (EN)

    Open application

  • Determination of total sulfur in wine by molecular absorption spectrometry (MAS) (JP)

    Open application

  • Determination of total sulfur in wine by molecular absorption spectrometry (MAS) (EN)

    Open application

  • Bestimmung von Gesamtschwefel in Wein mittels Molekülabsorptionsspektrometrie (MAS) (DE)

    Open application

  • Determination of toxic traces of cadmium, lead, and thallium in food (EN)

    Open application

  • Determination of mineral contents in nonalcoholic (EN)

    Open application

  • Determination of Metals in Dietary Supplements Using HR-CS Solid AAS (EN)

    Open application

Geology, Mining & Metals

Show applications

Applications

Oil & Gas

Show applications

Applications

  • ASTM D 6732-04に準拠したジェット燃料中の銅の微量分析 (JP)

    Open application

  • Quantification of Copper Traces in Jet Fuel according to ASTM D 6732-4 (EN)

    Open application

Power & Energy

Show applications

Applications

Technical Data

Spectral resolution

Sensitivity

Light source

Wavelength range

Optical design

Detector

Background correction

Wavelength precision

Dimension (width x depth x height)

contrAA 800 D - HR-CS AAS for flame- and graphite furnace techniques
815-08002-2

0.002 nm @ 200 nm Flame: 0.015 mg/l 1%Abs (Cu 324)
Graphite furnace: 0.66 µg/l 1%Abs (Pb 283)
Xenon short arc lamp 185-900 nm High-Resolution Echelle Spectrometer CCD Spectral 0.4 pm 780 mm x 775 mm x 625 mm

contrAA 800 F - HR-CS AAS for flame technique
815-08000-2

0.002 nm @ 200 nm Flame: 0.015 mg/l 1%Abs (Cu 324) Xenon short arc lamp 185-900 nm High-Resolution Echelle Spectrometer CCD Spectral 0.4 pm 780 mm x 775 mm x 625 mm

contrAA 800 G - HR-CS AAS for graphite furnace technique
815-08001-2

0.002 nm @ 200 nm Graphite furnace: 0.66 µg/l 1%Abs (Pb 283) Xenon short arc lamp 185-900 nm High-Resolution Echelle Spectrometer CCD Spectral 0.4 pm 780 mm x 775 mm x 625 mm

For more information about our products and possible variants, please refer to the technical documents or use our contact form.

Order Information

Order number

Description

815-08002-2 contrAA 800 D HR-CS AAS for flame and graphite furnace techniques
815-08000-2 contrAA 800 F HR-CS AAS for flame technique
815-08001-2 contrAA 800 G AAS for graphite furnace and technique

Patented Technology and Ingenious Solutions

Unparalleled flexibility – one lamp, all the elements

A xenon short arc lamp generates a continuous emission spectrum over the entire range of wavelengths of relevance for the AAS. Every element and wavelength can be analyzed at any time as selected in the software. This includes molecular absorption bands that can be used for the analysis of non-metals. Secondary wavelengths with high light intensity are also available, allowing the dynamic range to be extended to higher concentrations. The extraordinary light intensity of the xenon lamp also guarantees an excellent signal-to-noise ratio, thus significantly improving detection limits and precision.

  • Multielement analysis across the entire spectrum (185—900 nm)
  • Expanded range of application and implementation
  • Greater productivity

Unparalleled precision and accuracy – at the highest resolution, with the least interference

The combination of a high-resolution spectrometer and a CCD array detector provides for high-resolution absorption spectra with extremely detailed information. A three-dimensional representation of the spectra provides for the correct evaluation of the absorption lines and their spectral environment. It also provides information on other elements present in the sample that can be measured at the same time as well.

Modern software tools make data evaluation easier. Spectral background and lamp intensity fluctuations are automatically and directly corrected in the spectrum. Interference from other atomic and molecular absorption structures is reduced to a minimum from the outset as a result of the high level of resolution. Complex spectral interferences can be corrected using matrix correction spectra.

  • Determination and rapid sequential quantification of all of the elements contained in the sample
  • Simple method development
  • Reliable results

Accessories

Air compressor, 50/60Hz, 110V - to supply AAS with water- and oil- free compressed air 810-60276-0
AS-F Autosampler for flame, hydride AAS and CV-AAS/AFS 810-60500-0
Sample rack 139 positions for AS-F and AS-FD 810-60503-0
AS-FD Autosampler with auto-dilution for flame, hydride AAS and CV-AAS/AFS 810-60501-0
SSA 600 automatic solid sampler for contrAA-Series 810-60274-0
Burner head AC (100 mm) for higher sensitivity in the acetylene/ air flame 810-60056-0
Burner head NO/AC (50 mm) for acetylene/nitrous-oxide or acetylene/air flame 810-60057-0
Sample rack 54 positions for AS-F and AS-FD 810-60502-0
Burner fork - for fast replacement of burner heads 810-60058-0
Segmented Flow Star SFS 6.0 - switching valve 810-60129-0
Scraper - for automatic burner head cleaning 810-60127-0
Hg/Hydride System HS 50 - Manual hydride system with flame heated quartz cell atomizer 810-60149-2
SSA 6c Manual solid sampler for contrAA 800 810-60249-2
Air compressor, 50/60Hz, 230V - to supply AAS with water- and oil- free compressed air 810-60055-0
Bench for ICP/AAS for AAS, ICP-OES and ICP-MS instrumentation 810-88005-0
AS-GF Autosampler for graphite furnace AAS 810-60510-0
Hg/Hydride System HS 60 - Flow injection system for Hg and hydride forming elements 810-60402-2
Hg/Hydrid-System HS 55 - Batch mode system for Hg and hydride forming elements 810-60404-2
Hg cell (tulip) - for improved Hg sensitivity 810-60051-0
Hg Plus Upgrade Module for Hg enrichment, extension of Hg/Hydride-Systems HS 55 and HS 60 810-60406-0
HydrEA Upgrade Kit for coupling hydride systems HS 55 and HS 60 with graphite furnace AAS 810-60509-0

Software

ASpect CS

Optimized for multi-element analysis with HR-CS AAS

 

ASpect CS is optimized for multi-element analysis with HR-CS AAS and provides straightforward, routine handling of data on a user interface with maximum flexibility even for challenging analyses beyond daily routines. It allows for the simultaneous evaluation of multiple element lines in one spectrum and free definition of the integration ranges of individual lines. Advanced correction algorithms automate the process of correcting both complex structured backgrounds and spectral interferences (CSI tool), providing more reliable figures than ever before. You can visualize your measurements and optimize your methods thanks to the three-dimensional, high-definition display of the spectra (HD Spectrum).

  • SOPs for easy method development
  • A large range of innovative evaluation methods such as the CSI tool
  • High safety measures and Good Laboratory Practice (GLP)
  • FDA 21 CFR Part 11 compliance (optional)
Product Required Included
contrAA 800 D - HR-CS AAS for flame- and graphite furnace techniques (815-08002-2)
contrAA 800 F - HR-CS AAS for flame technique (815-08000-2)
contrAA 800 G - HR-CS AAS for graphite furnace technique (815-08001-2)

FDA 21 CFR Part 11 Compliance for ASpect CS

Order number: 815-01003-2

The ASpect CS software with the FDA 21 CFR Part 11 module fully complies with FDA requirements. User rights management and individual passwords ensure that the system can only be accessed by authorized persons. All important events, such as logon/logoff, measurements, calibrations, and messages generated by the Self Check System, are recorded in the Audit Trail. Measured data can undergo routine review and approval using electronic signatures.

Product Required Included
contrAA 800 D - HR-CS AAS for flame- and graphite furnace techniques (815-08002-2)
contrAA 800 F - HR-CS AAS for flame technique (815-08000-2)
contrAA 800 G - HR-CS AAS for graphite furnace technique (815-08001-2)

Consumables

810-60258-0 Consumable set F for Flame technique novAA/contrAA/ZEEnit series
810-60066-0 Consumable set G for graphite technique novAA/contrAA
810-60508-0 Consumables Set H for Hydride Systems
407-A81.020 Graphite pipetting insert for novAA / contrAA series
407-A81.025 Graphite tube - PIN platform - pyrolytically coated
407-A81.011 Graphite tubes - pyrolytically coated
407-A81.021 Ceramic O-rings for furnace
702-A63.624 Cleaning strips for flame AAS
702-A63.625 Cleaning wires for flame AAS
407-111.860 Impact bead (standard, short) for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III)
407-111.006 Inlet tube (PTFE), manual work for mixing chamber (black, Ryton)-nebulizer (graphite )-system (III)
407-111.501 Nebulizer for mixing chamber(black)-nebulizer-system (III)
407-111.402 Set o-rings organic samples for mixing chamber (black)-nebulizer-system (III)
407-143.021 Set sealing rings for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III)
407-111.837 Waste tube siphon for mixing chamber (black, Ryton)-nebulizer (graphite)-system (III)
407-10-404-858 Intake filter air purge for contrAA 800
407-1508.108 Level sensor, organic samples for mixing chamber (black)-nebulizer-system (III)
407-10-1610-105-25 XBO-exchange unit for contrAA 800 series

Downloads

Brochure contrAA800 (EN)
Broschüre contrAA800 (DE)
EU Declaration of Conformity contrAA800 Serie
Flyer Analyse élémentaire des déchets (FR)
Flyer Calibration Standard Offering for TOC, AAS, and ICP Devices (EN)
Flyer Kalibrierstandards für TOC-, AAS- und ICP-Geräte (DE)
Microsoft Word - TechNote_contrAA800_ Background Correction_0001_en_final
Microsoft Word - TechNote_contrAA800_side pixel evaluation_0001_en (005)
Operating Manual contrAA 800 (DE)
Operating Manual contrAA 800 (EN)
Operating Manual contrAA 800 (ES)
Operating Manual contrAA 800 (FR)
Operating Manual contrAA 800 (IT)
Product Guide Chemical Analysis (EN)
Produktkatalog Chemische Analyse (DE)
Technical Data contrAA 800 (EN)
Technical Data contrAA 800 (EN)

Contact us We are happy to help you and will contact you as quickly as possible.